Epson TM-T90 Printer User Manual


 
CONFIDENTIAL
Paper roll Two-dimension code commands GS ( k
Ver. 10.01 p. 516
GS ( k <Function 065>
[Name] PDF417: Set the number of columns in the data region
[Format] ASCII GS ( k
pL pH cn fn n
Hex 1D 28 6B
03 00 30 41 n
Decimal 2940107
3 0 48 65 n
[Range] (
pL
+
pH
× 256) = 3 (
pL
=3,
pH
=0)
cn
= 48
fn
= 65
0
n
30
[Default]
n
= 0
[Description] Sets the number of columns in the data region for PDF417.
When
n
= 0, specifies automatic processing
When
n
is not 0, sets the number of columns in the data region to
n
codeword.
[Notes]
Settings of this function affect the processing of Functions 081 and 082.
When auto processing (
n
= 0) is specified, the maximum number of columns in the data area is 30 columns.
The following data is not included in the number of columns:
Start pattern and stop pattern
Indicator codeword of left and right
When automatic processing (
n
= 0) is specified, the number of columns is calculated by the print area when
processing Functions 081, 082, module width (Function 067), and option setting (Function 070).
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned
off.