Epson TM-T90 Printer User Manual


 
CONFIDENTIAL
Paper roll Miscellaneous commands DLE DC4 (fn = 8)
Ver. 10.01 p. 395
With a serial interface, the printer executes this command even when it is in offline, receive buffer full, or
error status.
With a parallel interface, if the printer is BUSY, this command cannot be used in the following states.
When DIP switch (BUSY condition) is on: receive buffer full
When DIP switch (BUSY condition) is off: offline, receive buffer full, or error status
When buffer clear processing is finished, the printer transmits the clear response as shown below to the
host.
When you use this command, obey the following rules.
When host PC transmits the function data, transmit the next data after receiving the corresponding
data (header ~ NULL) from the printer.
When operating with a serial interface, be sure to configure operation so that the host computer uses
the printer only when it is READY.
When operating with a parallel interface, the data sent by this function (starting with Header and
ending with NUL), as with other data, is first stored in the send buffer, then output in sequential order
when the host computer changes to the reverse mode. Note that the send buffer capacity is 99 bytes,
and any data exceeding this volume limit will be lost; therefore, when using this command, it is
important to configure the operation so that the host computer’s change to the reverse mode and the
subsequent status send /receive process is performed quickly.
When communication with the printer uses XON/XOFF control with serial interface, the XOFF code may
interrupt the “Header to NUL” data string.
Clear response Hex Decimal Data
Header 37H 55 1 byte
Identifier 25H 37 1 byte
NUL 00H 0 1 byte