CONFIDENTIAL
Paper roll Two-dimension code commands GS ( k
Ver. 10.01 p. 546
GS ( k <Function 282>
[Name] MaxiCode: Transmit the size information of the symbol data in the symbol storage area
[Format] ASCII GS ( k
pL pH cn fn m
Hex 1D 28 6B
03 00 32 52 m
Decimal 2940107
305082m
[Range] (
pL
+
pH
× 256) = 3 (
pL
=
3,
pH
= 0)
cn
= 50
fn
= 82
m
= 48
[Description] Transmits the size information for the encoded MaxiCode symbol data in the symbol storage area using the
process of <Function 280>.
[Notes]
■ In standard mode, use this function when the printer is “at the beginning of a line,” or “there is no data in
the print buffer.”
■ The size information for each data is as follows;
Send data Hex Decimal Data
Header 37H 55 1 byte
Identifier 37H 55 1 byte
Horizontal size(*1) 30H − 39H 48 − 57 1 − 5 byte
Separator 1FH 31 1 byte
Vertical size(*1) 30H − 39H 48 − 57 1 − 5 byte
Separator 1FH 31 1 byte
Fixed value 31H 49 1 byte
Separator 1FH 31 1 byte
Other information(*2) 30H or 31H 48 or 49 1 byte
NUL 00H 0 1 byte