DXP DVI, DXP DVI Pro, and DXP HDMI Series • SIS Configuration and Control 59
Command
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
Save, Recall, and Directly Write Global and Room Presets (continued)
Save current configuration as
a room preset
X^
*
X*
,
Rm
X^
Spr
X*]
Save the current configuration
as preset
X*
for room
X^
.
The command character is a
comma.
Example:
3*9
,
Rm03Spr09
]
Save current ties as preset 9
for room 3.
Directly write a
global preset
E
+
X&
P
X@
*
X#
!
X@
*
X#
%
X@
*
X#
$...
X@
*
X#
&
}
Spr
X&]
The tie all (!), tie RGB (&),
tie video (%), and tie audio ($)
commands are all valid.
Example:
+27P1*5!5*2$3*6%3*8&
Esc
Spr27
]
Brackets are shown to separate
ties for clarity only. Create
global preset 27, which ties
video and audio Input 1 to
Output 5, audio Input 5 to
Output 2, video Input 3 to
Output 6, and video Input 3 to
Output 8.
NOTE: The direct write of a global preset should always be preceded by a clear global preset ties command of that
same preset number, as shown below. In a directly-written preset, the tied input for each output position (or no
tied input) remains unchanged unless overwritten or cleared.
If you do not clear the ties in a global preset number before you directly write a global preset to that number,
ties that are part of the previous version of the specified preset with the same number can become part of the
newly-created preset.
Clear a global preset
E
+
X&
PO*!
}
Spr
X&]
Clear all ties in preset
X&
.
Example:
E
+27P0*!
}
Spr27
]
Clear all ties in preset 27.
Write room outputs
E
X^
,
X#
,
X#
,...
X#
n
MR
}
Mpr
X^
,
X#
,
X#
,...
X#
n
]
Assign outputs to room
X^
.
See the notes below.
NOTES: A room can contain a maximum of 16 outputs.
An output can belong to only one room.
The maximum number of rooms (
X^
) is 10.
If no room name is assigned (see the Names commands on page 63), the default name is
Room #
X^
X#
1
,
X#
2
,
X#
3
.
Example:
E
8,3,4,5,6MR
}
Mpr8,3,4,5,6
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
Read room outputs
E
X^
MR
}
X1#
X^
,
X#
,
X#
,...
X#
n
]
Display the outputs assigned
to room
X^
.
Example:
E
3MR
}
Class1,1,2,6,8
]
Outputs 1, 2, 6, and 8 are
assigned to room 3, which is
named “Class 1.”
NOTE:
X@
= Input number (for ties) 0 – maximum number of inputs for your model
X#
= Output number 1 – maximum number of outputs for your model
X^
= Room number (for room presets) Each room can have up to 10 presets (
X*
) assigned.
X&
= Global preset number 0032. 00 = current preset
X*
= Room preset number 00 – current ties for the room in view mode, 10 maximum
X1#
= Room name 11 characters maximum for room names. Upper- and lowercase
letters are valid.