Extron electronic GSS 100 Network Card User Manual


 
GSS 100 Graphic Still Store • Operation
Operation, cont’d
GSS 100 Graphic Still Store • Operation
3-10
3-11
Advanced menu
Figure 3-10 is a flowchart that shows an overview of the
Advanced menu and the available settings.
Menu
10 sec. 10 sec.
Power
on
Menu
Default
Cycle
Next
Menu
Menu
Menu
Menu
Menu
10
sec.
10
sec.
Advanced
Menu
Exit
Menu
10
sec.
10
sec.
10
sec.
Auto Sw
Off
Next Next
3 sec.
{scroll}
Name
GSS-100-
Auto Switch
• Off • Off/show
• On/still • On/show
Switch
Effect
Name (Display Only)
(Changeable under RS-232/Ethernet control;
scrolls to the left if greater than 8 characters.)
Next
Next Next
Next
Int Temp
113F 45C
MAC Address
(Display Only)
Temperature
(Display Only)
Slide
Show
Output
Config
Baud Rate
• 2400 • 19200
• 4800 • 38400
• 9600 • 115200
Press Take to
enable changing
the value.
Rotate Adjust/
Select to change
the value.
Menu
Menu Menu
Menu Menu
I192.168
P254.254
RS-232
9600
Name
nn-nn-nn
nn:nn:nn
nn:nn:nn
TAKE
Press Take to enable
changing the value
and select an octet.
Rotate Adjust/Select
to change the value in
the selected (blinking)
octet.
TAKE
Figure 3-10 — Advanced submenu flowchart
Auto Switch (and slide show) submenu
The GSS can be set to an auto-switch mode that monitors the
sync signal on the RGB pass-through input and automatically
switches to the last-displayed stored image or slide show for
output when sync is lost. This submenu also allows you to turn
the auto-switching and slide show on and off.
Rotate the Adjust/Select mode while in the Auto-Switch
submenu to select:
Off (auto-switch mode off and slide show off)
Deactivates the automatic sync detection the slide show.
Off/show (auto-switch off and slide show on) — Leaves
the automatic sync detection off and manually initiates
the slide show. If the pass-through input was being
displayed when this selection is made, the GSS displays
the first image alphabetically by file name.
On/still (auto-switch on and slide show off — Activates
the automatic sync detection and auto-switches to the
still image. If sync is lost, the GSS switches to the last
displayed image that was output and outputs that image
until sync is restored or you select another image to
display.
On/show (auto-Switch on and slide show on)
Activates the automatic sync detection and auto-switches
to the slide show. If sync is lost, the GSS switches to the
last-displayed image and begins to cycle through the
available images.
The default setting is off.
Name display
The read-only Name display shows either the factory default
name or a customized name that can be assigned under RS-232
or Ethernet control. If the name is greater than eight characters,
the display shows the first eight characters of the assigned name
and then scrolls the name to the left to display the remaining
characters of the name.
The factory default name is the product name (GSS-100-) plus
last three pairs of MAC address. See chapter 4, SIS™ Control,
and chapter 5, HTML Control and IPL File Manager, to assign a
name.
MAC Address display
The read-only MAC Address display shows the hardcoded,
factory assigned hardware address.
Internal Temperature display
The read-only Internal Temperature display shows the
Fahrenheit and Celsius measurements for the GSS temperature.
CAUTION
Temperatures above 150 degrees Fahrenheit
(65 degrees Celsius) are potentially damaging to the
GSS.