Extron electronic GSS 100 Network Card User Manual


 
GSS 100 Graphic Still Store • Operation
Operation, cont’d
GSS 100 Graphic Still Store • Operation
3-12
3-13
Baud Rate menu
The Baud Rate menu is read-only without further action. The
menu shows the selected baud rate for the GSS’s RS-232 port.
The default setting is 9600.
To change the baud rate, press and release the Take button.
The baud rate display starts blinking, and can be adjusted by
rotating the Adjust/Select knob.
N
The baud rate is also selectable using SIS commands or
the HTML pages. See chapter 4, SIS Control, and
chapter 5, HTML Control and IPL File Manager.
IP address menu
The read-only IP address menu is read-only without further
action. The menu shows the GSS’s IP address. The factory
default IP address is 192.168.254.254.
To change the IP address, one octet at a time, press and release
the Take button. The first (most-significant) octet starts blinking,
and can be adjusted by rotating the Adjust/Select knob.
Repeatedly press and release the Take button to cycle through
the four IP address octets, enabling them for editing, one at a
time.
N
The IP address is also selectable using SIS commands
or the HTML pages. See chapter 4, SIS
Control, and
chapter 5, HTML Control and IPL File Manager.
Exit menu
Press and release the Next button while in the Exit menu to
return the LCD to the default display cycle.
Front panel security lockout (executive mode)
The front panel security lockout limits the operation of the
GSS from the front panel. When the GSS is locked, the front
panel Menu and Next buttons are disabled, although the
Image and Take buttons are still functional. If you push the
Menu or Next button when the GSS is locked, the LCD shows
X Mode Enabled for approximately 3 seconds and then returns
to the default display cycle.
To toggle the lock on and off, press and hold the Image button
and the Next button for approximately 2 seconds.
Front panel absolute reset
The GSS 100 can be reset from the front panel, resetting the
unit to its factory default conditions and deleting all uploaded
images. Reset the GSS by pressing and holding the Menu and
Next buttons while applying power to the unit (figure 3-11).
Power
MENU
NEXT
Reset to
Factory
Press and hold the Menu and Next
buttons while you apply power to the GSS.
Continue to hold the
Menu and Next buttons
until the LCD displays
the Reset message.
Release the Menu
and Next buttons.
Figure 3-11 — System reset