Extron electronic GSS 100 Network Card User Manual


 
GSS 100 Graphic Still Store • SIS
Control
SIS
Control, cont’d
GSS 100 Graphic Still Store • SIS
Control
4-8
4-9
Command/response table for SIS commands
Command ASCII Command
(host to switcher)
Response
(switcher to host)
Additional description
Image recall
Recall an image to buffer
EX!
RF
}
Cim•
X!
]
Select image
X!
to display.
N
It will take a few seconds between issuance of the recall command (
EX!
RF}) and receipt of the Cim response.
Show the currently
displayed image
E
RF}
X!
]
Buffer is loaded with image
X!
.
Take %
Tke
]
Swap the displayed and buffered images using the
selected effect (cut or dissolve).
Switch effect
Set the effect to cut 9*0#
Eff0
]
Set the effect for switching images to cut (immediate)
.
Set the effect to dissolve 9*1#
Eff1
]
Set the effect for switching images to dissolve.
Read the effect 9#
X@]
Set the dissolve duration
10*
X#
# Dur
X#
]
Set the duration of the dissolve effect to
X#
.
Read the dissolve duration 10#
X#
]
The dissolve duration is
X#
.
Source selection
Display pass-through 1!
Chn1
]
Display the pass-through input.
Display last image 0!
Chn0
]
Display the previously selected stored image.
View pass-through status !
X@
]
Pass-through mode is
X@
.
Slide show interval
Set slide show interval
2*
X#
# Sli
X#
]
Set the display time for each image to
X#
seconds.
Read slide show interval 2#
X#
]
The display time for each image is
X#
seconds.
Command ASCII Command
(host to switcher)
Response
(switcher to host)
Additional description
Pass-through configuration
Enable pass-through 1*1#
Pas1
]
Include the pass-through input in the slide show.
Disable pass-through 1*0#
Pas0
]
Do not include the pass-through input in the slide show.
Read pass-through status 1#
X@
]
Read pass-through status:
1 = include pass-through,
0 = do not include pass-through..
Auto-switch and slide show mode
Set auto-switch and slide
show
4*
X$
# Aut
X$
]
Set auto-switch and slide show modes:
0 = Off — Auto-switch on loss of pass-through sync
and slide show are disabled.
1 = Off/show — Auto-switch on loss of pass-through
sync is disabled. Slide show is
running.
2 = On/still — On loss of sync on the pass-through
input, auto-switch to display the
the last-displayed image until pass-
through sync is restored.
3 = On/show — On loss of sync on the pass-
through input, auto-switch to run
the slide show until sync on the
pass-through input is restored.
Read auto-switch and slide
show status
4#
X$]
Command/response table for SIS commands (continued)