Operation manual
8070 CNC
11.
PLC
"Logic analyzer" service
(SOFT V03.0X)
236
The value is given in milliseconds or microseconds according to the active units and
the selected value will be displayed in the information area.
While the graphic window is selected, use the "+" and "-" keys to divide or multiply
this time base by two.
Start distance / Trigger distance
This data is only shown when there is a trace.
The value is updated when moving the indicator cursor of the graphic area. Its value
may also be edited, thus updating the cursor position in the graphic area.
Reference distance
This data is only shown when there is a trace already and the operator has put a
reference signal. It represents the time difference between the indicator cursor and
the reference signal.
The value is updated when moving the indicator cursor of the graphic area. Its value
may also be edited, thus updating the cursor position in the graphic area.
Trace status
This element cannot be edited, it automatically reflects the status of the trace. The
possible messages are:
Empty.
Beginning.
Executing.
Stopping.
Full.
There is a mark that changes states every 2ms.
With a time base of 10ms, 20ms and 4ms it will look like this.
Start distance It represents the time difference between the indicator
cursor and the base point of the trace (beginning of the
trace if there is no trigger point or it has not been
reached).
Trigger distance It represents the time difference between the indicator
cursor and the trigger point (if it has taken place).