Fagor America CNC8070 Computer Hardware User Manual


 



Operation manual
8070 CNC
PLC
"Monitoring" service
11.
(SOFT V03.0X)
241
11.10.1 Description of resource tables
As mentioned earlier, the user resources and symbols defined are displayed in
different tables. Each table shows the following information.
Timers
This table shows the timers and user defined symbols for the timers and their status.
This table has the following fields:
The inputs and outputs that are high will be indicated with a green symbol.
Registers
This table shows the registers and user symbols defined for the registers as well as
their values.
The values may be shown in decimal, hexadecimal or binary format.
Binary resources
This table shows the binary resources (inputs, outputs, messages, errors) and the
user defined symbols for the binary resources as well as information on the their
status.
Counters
This table shows the counters and user symbols defined for the counters as well as
their status.
This table has the following fields:
The inputs and outputs that are high will be indicated with a green symbol.
G It indicates whether any of the trigger inputs of the timer is active (TG1,
TG2, TG3 or TG4).
M Timer status:
S - Stopped.
T - Timing.
D - Disabled.
E Status of the Enable input (TEN).
R Status of the Reset input (TRS)
T Status output.
ET Elapsed time.
TO Remaining time.
E Status of the enable input (CEN).
U Status of the Count-up input (CUP).
D Status of the Countdown input (CDW).
P Status of the preset input (CPR).
S Status output.
C Value of the internal count of the counter.