Fagor America CNC8070 Computer Hardware User Manual


 



Operating manual
CNC 8070
HOW TO OPERATE THE CNC
Windows for warnings and errors
2.
(SOFT V03.0X)
21
2.4 Windows for warnings and errors
When an error occurs, the CNC will display a window describing the cause of the error.
There are three types of errors. The top of the window shows the category and it will
have a different color depending on the type of error it shows.
WARNING Green window.
ERROR Red window.
FATAL ERROR Purple window.
When several warnings and/or errors occur simultaneously, they are displayed from
the one with the lowest priority to the one with the highest priority. The top right side
of the window shows the priority level of the message. A down arrow indicates that
there are errors with lower priority and an up arrow indicates that there are errors with
higher priority. The operator can toggle the different active errors using the [©][ª]
keys.
WARNING
It is just that, a warning.
They do not stop part-program execution and the warning window may be closed by
pressing [ESC].
ERROR
It may be a syntax error in a program, PLC generated errors, etc. They are errors that
must be corrected.
They interrupt the execution of the program. Although the window displaying them
may be closed by pressing [ESC], it does not mean that the error status has been
taken care of. To do that, press [RESET]. After pressing [RESET] the CNC assumes
the initial conditions set by the machine manufacturer with the machine parameters.
While the error window is active, no other action will be possible but removing it (it
is not possible to change operating modes).
Refer to the error solving manual for a detailed description of the cause of the error
and its possible solutions.
FATAL ERROR
They are errors that force the operator to turn the CNC off.