Fujitsu N800 Server User Manual


 
U41243-J-Z156-1-76 13
Important notes Electrostatic-sensitive component label
2.2 Electrostatic-sensitive component label
Electrostatic-sensitive components may be identified by the following sticker:
Figure 1: Electrostatic-sensitive component sticker
You must follow the instructions below when handling modules containing
electrostatic-sensitive components:
Ê Discharge static electricity from your body (for example by touching a
grounded metal object) before handling modules containing electrostatic-
sensitive components.
Ê The equipment and tools you use must be free of static charge.
Ê Remove the power plug before installing or removing modules containing
electrostatic-sensitive components.
Ê Only hold modules containing electrostatic-sensitive components by their
edges.
Ê Do not touch any of the pins or track conductors on a module containing
electrostatic-sensitive components.
Ê Use a grounding strap designed for the purpose, to connect you to the
system unit as you install the modules.
Ê Place all components on a static-safe base.
I An exhaustive description of the handling of modules containing electro-
static-sensitive components can be found in “Richtlinie zur Handhabung
von elektrostatisch gefährdeten Bauelementen und Baugruppen (EGB)”
or “ITS Circular 4/95”.
I An ESD kit is available from Fujitsu Siemens Computers sales or an
authorized dealer, under catalog number 8501 and stock number
06431046.