U41243-J-Z156-1-76 39
Preparation for use and operation Configuring the server and components
4.4.1 Changing the switch settings
V CAUTION!
Observe the safety information and the information on handling electro-
static-sensitive components in the chapter “Important notes” on
page 11).
Ê Shut down the server and switch it off.
Ê Switch off all connected peripheral devices.
Ê Disconnect the server from the line voltage by removing the power cable
from the power outlet.
Ê Remove the PCI hot-plug cover (see the section “Removing/mounting the
PCI bus hot-plug cover” on page 87).
Ê Set the switches to the desired settings (see figure 14 on page 40).
Ê Mount the PCI hot-plug cover (see the section “Removing/mounting the PCI
bus hot-plug cover” on page 87).
Ê Reconnect the server to the line voltage and switch the system on for the
change to take effect.
3
OFF No
Password
Clear
Retains the password.
ON Password
Clear
Clears the current system password.
4
OFF NOP Reserve
ON NOP Reserve
5
OFF PHP
Switch
Hot-plug PCI slots, mechanical switches activated
ON PHP
Switch
Hot-plug PCI slots, mechanical switches deacti-
vated.
Switch Function Description
No. Pos.
Table 2: DIP switches settings