U41243-J-Z156-1-76 79
Troubleshooting and tips Drives are reported as “dead”
7.10 Drives are reported as “dead”
This error message may occur when the server has a disk array controller.
SCSI cabling incorrect
Ê Make sure that the SCSI cabling and the SCSI channel assignment still
correspond to the original state.
The configuration of the disk array controller is incorrect
Ê Check and correct the settings for the drives with the DAC utility DACCF or
EzAssist.
Refer to the documentation for the disk array controller for further information.
7.11 Added drive reported defective
This error message may occur when the server has a disk array controller.
Disk array controller is not configured for this hard disk drive
The drive was probably installed with the system switched off.
Ê Reconfigure the disk array controller for the hard disk drive with the DAC
utility DACCF or EzAssist. Refer to the documentation for the disk array
controller for further information.
or
Ê Reinstall the drive while the system is up and running.
If the hard disk drive continues to be shown as defective, replace it (see section
“Replacing SCSI hard disk drives” on page 91).
7.12 Error messages on the screen
The meaning of the error messages is contained in the manual on BIOS Setup
and in the documentation on the boards and programs used.