Fujitsu N800 Server User Manual


 
42 U41243-J-Z156-1-76
Configuring the server and components Preparation for use and operation
CMOS Clear:
This switch controls whether settings stored in non-volatile CMOS memory
(NVRAM) are retained when the system is reset or whether the default settings
are loaded.
If you want to change the settings in NVRAM, proceed as follows:
Ê Follow the procedure described in the section “Changing the switch settings”
on page 39.
Ê Set DIP switch 2 (see table 2 on page 38) to ON.
Ê Switch the system on. Wait for POST to complete and for the following
messages to be displayed on the screen:
NVRAM cleared by jumper
Press [F2] to enter Setup
This reprograms CMOS and RTC to the default settings, except for the
password.
Ê Press [F2] to start BIOS Setup and make any necessary changes. Press
[F10] to save the new settings and exit Setup.
Ê Shut down the system, turn the server off and disconnect it from the line
voltage.
Ê Reset DIP switch 2 (see table 2 on page 38) to OFF.
Ê Reconnect all peripheral devices, reconnect the server to the line voltage,
and switch the server on.
Ê Run BIOS Setup to save the desired settings (see section “BIOS Setup” on
page 47).