Residual-toner-feed motor
Before proceeding, remove the following components:
●
Intermediate transfer belt (ITB). See
Intermediate transfer belt (ITB) on page 92.
●
Upper-left cover. See
Upper-left cover on page 96.
Remove the residual-toner-feed motor
Remove one screw (callout 1), disconnect one connector (callout 2), and them remove the residual-
toner-feed motor (callout 3).
Reinstallation tip When the motor (callout 3) is reinstalled, make sure that the keyed shaft on the
product and motor component are correctly aligned and engaged.
Figure 2-96 Remove the residual-toner-feed motor
1
2
3
ENWW Internal assemblies 133