2. Remove two screws (callout 1), and then remove the paper guide (callout 2).
NOTE: Duplex models only: press the duplex solenoid (callout 3) to create enough clearance to
remove the paper guide (callout 2).
TIP: The fuser delivery sensor is installed on the rear of the paper guide. Leave the sensor
attached to the guide, and rotate the paper guide toward the rear of the product to access the
delivery assembly.
Figure 2-114 Remove the delivery assembly (2 of 7)
1
2
3
3. Release the wire harness from the guides (callout 1), and then disconnect one connector (callout
2).
Figure 2-115 Remove the delivery assembly (3 of 7)
2
1
146 Chapter 2 Removal and replacement ENWW