Reinstall the delivery assembly
NOTE: For duplex models, the solenoid plunger must be removed from the discarded assembly, and
then installed on the replacement assembly. For all models, the output-bin full sensor must be removed
from the discarded assembly, and then installed on the replacement assembly.
1. Duplex models only: Make sure that the solenoid plunger is correctly installed on the replacement
assembly.
Figure 2-120 Reinstall the delivery assembly (1 of 4)
2. For all models: Do the following.
a. The output-bin full sensor is held in place on the delivery assembly by one tab and two hooks
(callout 1).
Figure 2-121 Reinstall the delivery assembly (2 of 4)
1
ENWW Internal assemblies 149