HP (Hewlett-Packard) HP Integrated Lights-Out Network Card User Manual


 
Remote Insight Command Language 287
RIB_INFO Parameter
MODE is a specific string parameter with a maximum length of 10 characters
that specifies what you intend to do with the information. Valid arguments are
"read" and "write."
Write mode enables both reading and writing of iLO information. Read mode
prevents modification of iLO information.
RIB_INFO Runtime Errors
None
RESET_RIB
The RESET_RIB command is used to reset iLO. For this command to parse
correctly, the command must appear within a RIB_INFO command block, and
RIB_INFO MODE can be set to read or write. The user must have the configure
iLO privilege to execute this command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="Admin" PASSWORD="Password">
<RIB_INFO MODE = "write">
<RESET_RIB/>
</RIB_INFO>
</LOGIN>
</RIBCL>
RESET_RIB Parameters
None
RESET_RIB Runtime Errors
The possible RESET_RIB error message include: