HP (Hewlett-Packard) HP Integrated Lights-Out Network Card User Manual


 
396 User Guide Integrated Lights-Out
You can also manually force the iLO management processor to reset by clicking
Apply on the Network Settings page. You do not need to change any parameters
before clicking Apply.
Server Name Still Present after ERASE Utility is Executed
The Server Name field is communicated to iLO through the Insight Manager
Agents. To change the Server Name field after a redeployment of a server, load
the Insight Manager Agents to update the Server Name field with the new server
name.
To remove the Server Name field after a redeployment of a server, use the Reset
to Factory Defaults feature of the iLO RBSU utility to clear the Server Name
field.
This procedure clears all iLO configuration information, not just the Server
Name information.
Troubleshooting a Remote Host
Troubleshooting a remote host server might require restarting the remote system.
You can restart the remote host server by using the options listed in the Virtual
Devices tab.