HP (Hewlett-Packard) HP Integrated Lights-Out Network Card User Manual


 
Remote Insight Command Language 317
Example:
<SERVER_INFO MODE="read">
……… SERVER_INFO commands ………
</SERVER_INFO>
SERVER_INFO Parameter
MODE is a specific string parameter with a maximum length of 10 characters
that specifies what you intend to do with the information. Valid arguments are
"read" and "write."
Write mode enables both reading and modifying of server functionality. Read
mode prevents modification of server functionality.
SERVER_INFO Runtime Errors
None
<RIBCL VERSION="2.0">
GET_HOST_POWER_STATUS
The GET_HOST_POWER_STATUS command requests the power state of the
server. For this command to parse correctly, the
GET_HOST_POWER_STATUS command must appear within a
SERVER_INFO command block, and SEVER_INFO MODE can be set to read
or write.
Example:
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="write">
<GET_HOST_POWER_STATUS/>
</SERVER_INFO>
</LOGIN>