HP (Hewlett-Packard) HP Integrated Lights-Out Network Card User Manual


 
Troubleshooting iLO 377
Proxy Server Issues
If the Web browser software is configured to use a proxy server, it will not
connect to the iLO IP address. To resolve this issue, configure the browser not to
use the proxy server for the IP address of iLO. For example, in Internet Explorer,
select Tools, Internet Options, Connections, LAN Settings, Advanced, and
then enter the iLO IP address or DNS name in the Exceptions field.
Troubleshooting Alert and Trap Problems
Alert Explanation
Test Trap This trap is generated by a user through the Web configuration page.
Server Power Outage Server has lost power.
Server Reset Server has been reset.
Failed Login Attempt Remote user login attempt failed.
General Error This is an error condition that is not predefined by the hard-coded MIB.
Logs Circular log has been overrun.
Security Override Switch
Changed: On/Off
The state of the Security Override Switch has changed (On/Off).
Rack Server Power On
Failed
The server was unable to power on because the BL p-Class rack
indicated that insufficient power was available to power on the server.
Rack Server Power On
Manual Override
The server was manually forced by the customer to power on despite
the BL p-Class reporting insufficient power.
Rack Name Changed The name of the ProLiant BL p-Class rack was changed.
Inability to Receive Insight Manager 7 or Systems Insight
Manager Alarms (SNMP Traps) from iLO
A user with the Configure iLO Settings privilege must connect to iLO to
configure SNMP trap parameters. When connected to iLO, be sure that the
correct alert types and trap destinations are enabled in the SNMP/Insight
Manager Settings screen of the iLO console application.