HP (Hewlett-Packard) RP7400 Server User Manual


 
SCSI Devices
112
Default ID = 7
2. Press
<Return>
Example 1 Display SCSI transfer rate for a controller at 0/0/2/0 (Internal drive path)
Command:
SCSI RATE <0/0/2/0>
Response:
Path (dec) Initiator ID SCSI Rate
---------- ------------ ---------
0/0/2/0 7 No Limit
Example 2 Set the SCSI transfer rate for a controller at 0/0/2/0 to Ultra II
Command:
SCSI RATE 0/0/2/0 0
Response:
Path (dec) SCSI Rate
---------- ---------
0/0/2/0 No Limit
Example 3 Display SCSI initiator ID for all controllers, busses, and slots.
* Shows all controllers and Id's that have been programmed.SCSI controllers that are in PCI slots that have
not been altered from default will not show up. Only core controllers are displayed until the other slots are
programmed.4.Set the SCSI initiator ID of a controller at 0/0/2/1
Command:
SCSI
Response:
Path (dec) Initiator ID SCSI Rate
------------ -------------- ----------
0/0/2/0 5 Ultra
0/0/2/1 7 Ultra
0/0/1/0 7 No Limit
5/0/0 6 Fast
12/0/0 6 Fast
12/0/1 6 Fast
0/0/10/0/0 6 Unknown
0/0/10/0/1 6 Unknown
0/0/12/0/0 6 Unknown
0/0/12/0/1 6 Unknown
0/8/0/0 6 No Limit
0/8/0/1 6 No Limit
Example 4 Sets the SCSI initiator ID for a specified controller, bus, and slot.
Command:
SCSI init 0/0/2/1 6
Response:
Path (dec) Initiator ID
---------- -------------
0/0/2/1 6