IBM 4986B LanProbe Network Card User Manual


 
Local Terminal Configuration
Using a Local Terminal
23
Display Interface Summary
Use the following procedure to view the Display Interface Summary screen for
your LanProbe. Refer to Figure 2-9 on page 24.
1. Press
4
, the
Display Interface Summary
item. The Display Interface
Summary item displays the number and type of each interface, the port type,
and each port’s IP address.
2. Press Enter to continue.
3. From LanProbe’s Main Menu, press
7
to execute a warm start or press
8
to
execute a cold start. A cold start is required if you change the IP Address,
Default Gateway or Subnet Mask. For either menu choice, LanProbe exits
the Main Menu and restarts normal operations.
NOTE
A warm start resets all data collected by the probe. A cold start resets all data
collected by the probe and also resets any user-configuration information, such as
history studies, filters, and alarms to their default values. Refer to Chapter 5
“LanProbe Operation” for more information on what is reset by warm and cold
starts.
After the probe restarts (boots), it operates normally using the new
configuration information. The warm start or cold start occurs immediately
and there is no visual indication of when it finishes.
4. If you are performing the initial probe configuration, prepare LanProbe for
installation by disconnecting the power cord. You will not lose your initial
configuration information.