IBM DR550 Computer Drive User Manual


 
IBM System Storage DR550 Version 3.0 ------17 March 2006 Page 11
IBM Storage Systems Copyright © 2006 by International Business Machines Corporation
on the switch. These cables would also need to be connected to the customer network. You can
then access the switch using the IP address. The Userid is ADMIN and the password is
PASSWORD. You should change this password to confirm with site security guidelines.
If you should need to review the configuration or zoning within the switches, the IP address for
switch 1 is 192.168.1.31 and switch 2 (only installed in dual node configurations) is 192.168.1.32.
These addresses should not be changed. To gain access to the switches via the IP network, you
will need to provide Ethernet cables and ports on your existing Ethernet network. Once the
connections have been made, then you can connect to the IP address and use the management
tools provided by the switch.
Dual Node Zoning – without Enhanced Remote Volume Mirroring
2005-B16_1
1
0 2 3
4
5
6
2 3
7
Engine2Engine1 Slot 5
Slot 4
2005-B16_2
Zone 1
Zone 2
Zone 3
Slot 1
1
0 2 3
4
5
6
2 3
7
Zone 1
Zone 2
Zone 3
Note: Zone 3 is configured for use with the tape (TS1120, TS3310, 358x, 3592 with WORM
cartridges are recommended) - ports 5-7 are connected to the tape drives
Slot 5
Slot 4
Slot 1
DS4100_2
Controller A1
Controller B1
Controller A2
Controller B2
DS4100_1
Controller A1
Controller B1
Controller A2
Controller B2
Dual Node Zoning – with Enhanced Remote Volume Mirroring