IBM DR550 Computer Drive User Manual


 
IBM System Storage DR550 Version 3.0 ------17 March 2006 Page 112
IBM Storage Systems Copyright © 2006 by International Business Machines Corporation
Height: 43.7 mm (1.72 in)
Weight: 12.9 kg (44.8.4 lb)
Operating Environment
Temperature:
10-35 degrees C (50-95 degrees F) at 0-914 m (0-3000 ft)
10-32 degrees C (50-90 degrees F) at 914-2,133 m (3,000 – 7,000 ft)
Relative humidity: 8% to 80%
Electrical Power (per power supply)
Voltage Range
100 – 127 (nominal) V ac: 50Hz or 60 Hz, 5.6 A
200 - 240 (nominal) V ac; 50 Hz or 60 Hz, 1.7A
Power Source loading: 0.55 kVA
Maximum altitude: 2,135m (7,000 ft)
Noise Level (normal operation): 4.4 bels
Heat dissipation: 1878 BTU per hour
7316-TF3
Physical Specifications
Width: 485 mm (19 in)
Depth: 635 mm to 730 mm (29.0 in to 44.8.74 in)
Height (closed): 43.0 mm (1.7 in)
Height (opened): 410 mm (16.1 in)
Weight: 12.8 kg (44.8.2 lbs)
LCD Panel
Size: 432 mm (17 in) diagonal, 337.92 (H) x 270.34 mm (V) (13.3 in x 10.6 in)
Type: a-Si TFT active matrix
Pixel pitch: 0.264 mm (H) x 0.264 mm (V)
Operating Environment
Not applicable
7014-T00 Rack
Physical Specifications
Width: 644 mm (25.4 in) with side panels
Depth: 1098 mm (43.3 in) with front and read doors
Height: 1804 mm (71.0 in with standard AC power
Weight (empty): 244 kg (535 lbs)
Operating Environment
Temperature:
10-40 degrees C
Relative humidity: 8% to 80%
Maximum wet bulb: 27 degrees C
Electrical Power (per power supply)
Voltage Range – 200 to 240 V ac 50/60 Hz
Operating Current: 1.65-3.9 Amperes
Power: 390 Watts
Frequency: 50/60 Hz
Power source loading: 4.8 kVA per PDU (rack may have up to 4 PDUs)
Noise Level (normal operation): 0.0 bels
Heat dissipation: 1088 BTU per hour