IBM DR550 Computer Drive User Manual


 
IBM System Storage DR550 Version 3.0 ------17 March 2006 Page 96
IBM Storage Systems Copyright © 2006 by International Business Machines Corporation
2. From the DS4000 Storage Manager client Enterprise Management window, go to Edit ->
Configure Mail Server... at the upper left side.
3. Enter your mail (SMTP) server address in the first line. This is the name of the mail server that
forwards the e-mail to the configured e-mail alert destination. This server must be able to route data to
the network of the receiver. Enter a meaningful sender address information in the second line of the
window as shown in Error! Reference source not found.. The sender’s e-mail address is displayed
on every mail message that is sent to the configured e-mail alert destination.
If you do not specify an SMTP server name, the Enterprise Management software attempts to
send the e-mail using a mail server on the local Storage Management Station. The e-mail
sender’s address required in the SMTP protocol must be specified or an error will result.
4. Click OK.
E-mail alert destination
1. Select the e-mail tab from the Edit -> Alert Destinations... menu screen at the DS4000 Storage
Manager client Enterprise Management window. The Add/Edit Alerts dialog window opens.
2. Enter the e-mail address of the recipient for alert e-mail notification in the appropriate line. For
example, alert@customer.com as shown below.