IBM GC28-1982-02 Laptop User Manual


 
0031-646 0031-652
0031-646 PM Array is trying to tell us something ...
Explanation: A message from PM Array is directed to the Home Node. At present there
are no Home Node functions responding to the PM Array, so the message text is just printed
out.
User Response: Verify that the PM Array tool is working correctly.
0031-647
string
Explanation: This is the message buffer text from PM Array as described in message
0031-646.
User Response: Verify that the PM Array tool is working correctly.
0031-648 Couldn't tell world about EOF on STDIN
Explanation: An error occurred while broadcasting EOF on STDIN to the partition. The
partition is terminated, and POE exits.
User Response: Verify that the remote nodes are accessible and restart POE. If the failure
continues, gather information about the problem and follow local site procedures for reporting
hardware and software problems.
0031-649 Couldn't tell task
number
about EOF on STDIN
Explanation: An error occurred while sending EOF on STDIN to the indicated task. The
partition is terminated, and POE exits.
User Response: Verify that the remote node is accessible and restart POE. If the failure
continues, gather information about the problem and follow local site procedures for reporting
hardware and software problems.
0031-650 No receiver for STDIN bound for
number
Explanation: STDINMODE defines a task number that is not active.
User Response: Probable user error. Verify the value of STDINMODE set by the
environment variable or under program control.
0031-651 Error reading input command file
Explanation: An I/O error occurred reading the input command file describing the
initialization sequence for pdbx and pedb. Input reverts to STDIN.
User Response: If possible, determine which file is being read and correct it. If the problem
persists, gather information about the problem and follow local site procedures for reporting
hardware and software problems.
0031-652 Error reading STDIN
Explanation: An I/O error occurred reading STDIN. STDIN is subsequently ignored.
User Response: Verify that the file used for STDIN is readable. If the problem persists,
gather information about the problem and follow local site procedures for reporting hardware
and software problems.
Chapter 4. POE Messages 91