IBM GC28-1982-02 Laptop User Manual


 
0033-1001 0033-1007
Chapter 6. VT Messages
0033-1001 Node is inactive
Explanation: The node selected for monitoring is not active.
Error Class: The selected square does not represent a node that is communicating with the
performance monitor.
User Response: Select a different square.
0033-1002 Monitoring is currently ON. Changes will not be effective until monitoring is
stopped and restarted.
Explanation: You have tried to add or remove a node for monitoring while monitoring was
in progress. Changes are only registered when monitoring is off.
Error Class: Selecting or deselecting a node while monitoring is active.
User Response: Stop monitoring and restart it to let the requested change(s) take effect.
0033-1003
string
was requested for monitoring but is not a known host
Explanation: The monitoring program attempted to contact the named host for monitoring
but was unable to determine its network address.
Error Class: The gethostbyname() function failed to locate the host.
User Response: Ensure that the host can be contacted on the network.
0033-1004 Failed to fork PM statistics collector program because
string
Explanation: A process to run the Performance Monitor statistics collection program could
not be started.
Error Class: The fork() function failed for the indicated reason.
User Response: Correct the specified problem.
0033-1005 Unable to execute
string
program Error is
string
Explanation: The Performance Monitor statistics collection program could not be run.
Error Class: The dug executable could not be invoked for the indicated reason.
User Response: Correct the specified problem.
0033-1006 Failed to create socket for the data collector because
string
Explanation: The socket for communicating between the Performance Monitor and the dug
program could not be created.
Error Class: The socket() function failed for the indicated reason.
User Response: Correct the specified problem.
0033-1007 Bind failed for the data collector socket.errno=
number
Explanation: bind could not be done on the socket for communicating between the
Performance Monitor and the dug program
Error Class: The bind function failed for the indicated reason.
User Response: Correct the specified problem.
Copyright IBM Corp. 1996, 1998 137