IBM GC28-1982-02 Laptop User Manual


 
0031-377 0031-402
| 0031-377 Using
string
for euidevice.
| Explanation: Informational message to indicate the messaging passing device being used
| for the batch POE job submitted to LoadLeveler.
| User Response: None required.
| 0031-378 Ignoring SP_NAME in batch mode
| Explanation: User has submitted a POE job in batch mode under LoadLeveler and the
| SP_NAME environment variable or associated command-line option was set.
| User Response: Unset SP_NAME in the environment or remove -spname from the
| arguments line in the LoadLeveler submit file to eliminate the warning, if desired.
| 0031-379 Pool setting ignored when hostfile used
| Explanation: User has set the MP_RMPOOL environment variable or the -rmpool
| command-line option but a hostfile was found.
| User Response: Ensure that use of the hostfile was intended.
| 0031-380 LoadLeveler step ID is
string
| Explanation: The indicated step ID was assigned by LoadLeveler to the current interactive
| job. It may be useful when using the llq command to determine the job status.
| User Response: None required.
| 0031-381 Switch clock source requested, but not all tasks on SP
| Explanation: You or another user set MP_CLOCK_SOURCE=SWITCH, but one or more of
| the tasks were not on SP nodes that have access to the switch. The job is terminated.
| User Response: If mixed-node execution is acceptable, unset the MP_CLOCK_SOURCE
| environment variable. Otherwise, check that the nodes allocated were all on an SP.
0031-400 Invalid value
number
for stdoutmode
Explanation: User has entered a non-negative value with -stdoutmode or
MP_STDOUTMODE which is greater than or equal to the number of processes requested;
for SINGLE mode, this value must be between 0 and n-1, where n is the number of
processes.
User Response: Re-run with valid value.
0031-401 Invalid value
number
for stdinmode
Explanation: User has entered a non-negative value with -stdinmode or MP_STDINMODE
which is greater than or equal to the number of processes requested; for SINGLE mode, this
value must be between 0 and
n
-1, where
n
is the number of processes.
User Response: Re-run with valid value.
0031-402 Using css0 as euidevice for User Space job
Explanation: User specified command line option -euidevice or used environment variable
MP_EUIDEVICE with a setting of other than css0, which must be used for User Space jobs.
User value has been overridden to allow job to continue.
User Response: None required.
Chapter 4. POE Messages 81