0031-660 0031-667
0031-660 Partition Manager stopped ...
Explanation: The Home Node (POE) has stopped in response to a SIGTSTOP (<Ctrl>Z)
signal. The remote nodes have been stopped.
User Response: To resume the job, issue SIGCONT, or use the shell job control
commands fg or bg.
0031-661 signal_sent =
number
not recognized
Explanation: The indicated signal was recorded as being sent to the remote nodes, but is
not recognized by POE. Execution continues.
User Response: Probable POE internal error. Gather information about the problem and
follow local site procedures for reporting hardware and software problems.
0031-662 Node
number
did not send PROFILE_DONE, sent msgtype
number
Explanation: The indicated node did not send the PROFILE_DONE message after
profiling, but sent a message of the indicated type. Message 0031-663 gives the text sent.
User Response: Consult the explanatory text. If that fails to disclose the problem, gather
information about the problem and follow local site procedures for reporting hardware and
software problems.
0031-663
string
Explanation: This is the text of a message received instead of the expected
PROFILE_DONE message.
User Response: If the text fails to disclose the problem, gather information about the
problem and follow local site procedures for reporting hardware and software problems.
0031-664 Unknown message type
number
received
Explanation: The indicated message type is not known by POE. Execution is terminated.
User Response: Probably the socket contains a non-structured message, which would be
a stray. If the source of the stray socket message cannot be determined, gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
0031-665 Invalid value for SSM_SINGLE
number
Explanation: The indicated value is invalid as a destination for SINGLE I/O mode. The
specification is ignored.
User Response: Verify that the correct value for SINGLE I/O mode is used.
0031-666 Out of range value for SSM_SINGLE
number
Explanation: The indicated value is out of range: less than zero, or greater than the
number of tasks. The specification is ignored.
User Response: Verify that the correct value for SINGLE I/O mode is used.
0031-667 Invalid value for SSM_UNORDERED
number
Explanation: The indicated value is invalid as a specification for UNORDERED I/O mode.
The specification is ignored.
User Response: Verify that the correct value for I/O mode is used.
Chapter 4. POE Messages 93