IBM GC28-1982-02 Laptop User Manual


 
2537-0066 2537-0072
| 2537-0066 The following string(s) in the specified configuration file do not follow
| configuration file syntax
key
=
value
:
string
| Explanation: The string in the specified configuration file does not follow configuration file
| syntax
key
=
value
, where
key
is a configuration keyword such as PROG or FUNC and
value
| is the keyword's corresponding value, such as
program-name
or
function-name
.
| User Response: Make sure every non-comment string in the configuration file has the
| correct syntax.
| 2537-0067 No value is given in the Slider Value field.
| Explanation: You are using either the Filter By CPU Time Dialog or the Filter By Call
| Counts Dialog, and you clicked on the OK or Apply button without first entering an integer
| value in the Slider Value field.
| User Response: Enter a non-negative integer in the Slider Value field before clicking either
| the OK or Apply button to begin the search.
| 2537-0068 Cannot convert the string in the Slider Value field to an integer.
| Explanation: You are using either the Filter By CPU Time Dialog or the Filter By Call
| Counts Dialog, and you entered a string in the Slider Value field that cannot be converted to
| an integer.
| User Response: Enter a non-negative integer in the Slider Value field before clicking either
| the OK or Apply button to begin the search.
| 2537-0069 You must first select or enter a configuration file name.
| Explanation: You tried to use the Load Configuration option without specifying the name of
| the file whose contents you want to load.
| User Response: To use the Load Configuration option, first specify the name of the
| configuration file that you want loaded. To do this, you can either click on one of the files
| listed in this dialog, or type the name of a file in the Selection field.
| 2537-0070 The first line in the specified configuration file
string
does not start with
| VERS=.
| Explanation: The first non-comment line in an Xprofiler configuration file must start with the
| string VERS=; otherwise, it is considered a syntax error.
| User Response: Make sure the first non-comment line in the specified configuration file
| begins with the string VERS=, starting in column 1.
| 2537-0071 The configuration file
string
was created by a different version of Xprofiler.
| Explanation: The version number in the specified configuration file does not match
| Xprofiler's version number. In this release, there is no harm caused by this mismatch, but
| just be aware of this. The version number of Xprofiler is shown on stderr when Xprofiler is
| first brought up. In the configuration file, the version number of Xprofiler is recorded on the
| VERS= line.
| User Response: In this release, there is no harm caused by this mis-match, but just be
| aware of this situation.
| 2537-0072 The specified file
string
is in 64-bit format, which is not supported in this
| release.
| Explanation: The specified file is in 64-bit format, which is not supported in this release.
| The file will be ignored.
| User Response: Make sure that all files used in Xprofiler are in 32-bit file format.
184 IBM PE for AIX V2R4.0: Messages