0031-676 0031-687
0031-676 Invalid value
string
for mp_euidevice
Explanation: The mp_euidevice specified on the command line with -euidevice or in the
environment with MP_EUIDEVICE is not valid.
User Response: Refer to IBM AIX Parallel Environment Operation and Use for valid
choices and rerun.
0031-677 Unexpected return code
number
from _mp_stdoutmode
Explanation: An error may have occurred in a lower level function.
User Response: If earlier error messages exist, perform whatever corrective action is
indicated for these. If there are no other messages or if problem persists, gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
| 0031-678 Hostfile may not contain pool requests if not using job management
| system
| Explanation: The user explicitly requested not to use the job management system (with the
MP_RESD environment variable or the -resd command line flag), but the hostfile contained
pool requests.
| User Response: Use hostnames in the hostfile or do not request that LoadLeveler or the
Resource Manager not be used.
0031-679 Profiling may not have completed on node
number
Explanation: A profiling file may not have been completed for the given node. However,
profiling files may exist for other nodes in the job.
User Response: If a profiling file from this node is needed, ensure that there is enough
room on the node's filesystem for the profiling file and re-run the job. If the problem persists,
gather information about the problem and follow local site procedures for reporting hardware
and software problems.
0031-680 Invalid mode
number
requested
Explanation: User program has called function MP_STDINMODE or mpc_stdinmode with
invalid mode.
User Response: Refer to man page for explanation of valid modes.
0031-682 Unexpected return code
number
from _mp_in_mode
Explanation: An error may have occurred in a lower level function.
User Response: If earlier error messages exist, perform whatever corrective action is
indicated for these. If there are no other messages or if problem persists, gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
0031-687 Unsuccessful call to pm_SSM_read
Explanation: Internal error has occurred.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.