0031-903 0031-A400
0031-903 Can't confirm profiling for task
number
Explanation: A communication failure has occurred.
User Response: Retry; if problem persists, gather information about the problem and follow
local site procedures for reporting hardware and software problems.
0031-904 Can't rename profiling file to
string
Explanation: A communication failure may have occurred, or the profiling file could not be
opened.
User Response: Check path name and permissions. If problem persists, gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
0031-906 Task
number
finished profile...
Explanation: Designated task has finished profile.
User Response: None required, information only.
0031-907 Task
number
terminating due to pulse timeout
Explanation: Designated task has been terminated due to a timeout in the POE pulse
processing. The connection to the home node may have dropped, or the job may have been
hung or abnormally functioning.
User Response: It is possible that the pulse interval was too small to allow sufficient time
for the task to complete. Verify that the node is still up, or that the job was not doing
something abnormal. You may also want to increase your interval value with the MP_PULSE
environment variable or -pulse command line flag.
0031-908 SSM_PULSE acknowledgment failed for task
number
.
Explanation: There was a failure in sending the acknowledgment message for the POE
pulse function from POE to pmd for the indicated task.
User Response: Possible system error, unless the network connection between the nodes
dropped. Otherwise, gather information about the problem and follow local site procedures
for reporting hardware and software problems.
0031-909 POE terminating due to pulse timeout for task
number
.
Explanation: POE has determined that there were remote nodes which did not respond
during POE pulse processing. There was not enough responses prior to the pulse timeout
interval. The connection to the home node may have dropped, or the job may have been
hung or abnormally functioning.
User Response: It is possible the that the pulse interval was too small to allow sufficient
time for the task to complete. Verify that the nodes are still up, or that the job was not doing
something abnormal. You may also want to increase your interval value with the MP_PULSE
environment variable or -pulse command line flag.
0031-A400 Error in creating socket
Explanation: The program pmarray terminates. An explanatory sentence is appended.
User Response: Probable system error. Check the condition(s) given in the explanatory
sentence.
102 IBM PE for AIX V2R4.0: Messages