IBM GC28-1982-02 Laptop User Manual


 
0033-3095 0033-3100
0033-3095 VT_trc_capture write_buffusd_data() Insufficient disk space to write,
Tracing stopped. Space left is
number
, required is
number
Explanation: Not enough disk space left.
Error Class: Insufficient disk space.
User Response: Clean the disk.
0033-3096 VT_trc_init() HPSOclk_init
string
failure, Tracing is disabled. Error is
string
Explanation: Clock initialization failed during trace initialization. Tracing cannot continue
and is disabled at this time.
Error Class: An unknown error was encountered in HPSOclk_init and the errno global
variable was set with the error code.
User Response: If the problem persists, gather information about the problem and follow
local site procedures for reporting hardware and software problems.
0033-3097 VT_trc_capture() HPSOclk_gettime failed, Tracing stopped. Error is
string
Explanation: Cannot read the VT trace record time stamp.
Error Class: System problem.
User Response: Gather information about the problem and follow local site procedures for
reporting hardware and software problems.
| 0033-3098 VT_trc_init(): SP Switch Option was not detected. The time of day clock
| will be used to timestamp trace records
| Explanation: The program is indicating that it is not using the SP switch to synchronize VT
| trace records across nodes. This is not a problem unless the program SHOULD be using the
| switch.
| Error Class: The /dev/css0 device is not present, is present but at a back level or is not
| operating properly.
| User Response: Ensure that ssp.css is installed and that /dev/css0 is present. If it appears
| to be, refer to css documentation for problem determination procedures.
| 0033-3099 VT_trc_init(): SP Switch Option was detected and will be used to timestamp
| trace records
| Explanation: The program is indicating that it is using the SP switch to synchronize VT
| trace records across nodes. This is not a problem unless the program SHOULD NOT be
| using the switch.
| Error Class: The /dev/css0 device is present and functioning normally.
| User Response: Gather information about the problem and follow local site procedures for
| reporting hardware and software problems.
0033-3100 VT_trc_init(): Unknown configuration detected during clock initialization.
Explanation: The program is indicating that after the initializing the trace record time
stamp, an unknown switch configuration was detected. Since initialization completed
successfully, tracing continues but the resulting trace file should be checked for timestamp
integrity.
User Response: Even if the trace file appears correct, report the message following local
site procedures for reporting hardware and software problems.
162 IBM PE for AIX V2R4.0: Messages