0033-3116 0033-3123
0033-3116 DIG(), Connection with Application program timed out after
number
seconds.
Explanation: The DIG daemon did not receive a response from the Trace client reasonable
amount of time.
Error Class: The trace client may have died or system delay.
User Response: Rerun the application.
0033-3117 DIG(), Version Mismatch. Dig version=
hex number
, Trace Version=
hex
number
Explanation: The version of DIG daemon does not match with the trace routine version of
the application program.
Error Class: Installation problem.
User Response: Reinstall VT .
0033-3118 dig daemon started on
string
Explanation: Informational message that indicates when the most recent dig daemon
started.
User Response: None.
0033-3119 dig daemon received
string
signal
Explanation: The dig daemon received a signal that may affect its operation.
User Response: None
0033-3120 dig daemon was unable to set signal handler for signal
number
Return code
=
number
Error is
string
Explanation: The dig daemon could not set a signal handler.
User Response: Contact local support.
0033-3121 dig: Socket read error occurred while trying to check the version of
string
client on
string
errno=
number
Explanation: The dig daemon encountered an error while trying to check the version of a
trace or monitor client.
User Response: Contact local support.
0033-3122 dig: Socket was closed by
string
client on
string
before version could be
verified.
Explanation: The dig daemon could not set a signal handler.
User Response: Contact local support.
0033-3123 dig: Socket read error while trying to read control message from
string
errno=
number
Explanation: The AIX statistics daemon, dig, experienced a problem trying to accept
commands from one of its clients.
Error Class: A system error occurred that prevented reading the socket.
User Response: The system error is reported as part of the message. If the problem
cannot be corrected from the system message, contact local support.
Chapter 6. VT Messages 165