0031-019 0031-028
0031-019 pm_contact: connect failed
Explanation: The Partition Manager terminates.
User Response: The Partition Manager is unable to connect to a remote node. Message
0031-020 follows. Probable PE system error. Gather information about the problem and
follow local site procedures for reporting hardware and software problems.
0031-020 Couldn't connect to task
number
(
string
)
Explanation: The Partition Manager terminates.
User Response: For the indicated remote task number and indicated host name, socket
connection could not be established. Check for valid names.
0031-022 setsockopt(SO_LINGER)
Explanation: The Partition Manager continues.
User Response: An error occurred in setting the LINGER socket option. Gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
0031-024
string
: no response; rc =
number
Explanation: The Partition Manager terminates.
User Response: No acknowledgement of startup was received from the pmd daemon
running on the indicated node. Check for error message from that node. The return codes
are: -1, EOF on connection; 1 I/O error; 2 allocation error
0031-025 unexpected acknowledgment of type
string
from remote node
Explanation: The Partition Manager received an unexpected acknowledgement during
initialization. Initialization with a remote node has failed.
User Response: Check the remote node log file to determine the reason for failure.
Probable PE error.
0031-026 Couldn't create socket for PM Array
Explanation: The Partition Manager terminates. An explanatory sentence follows.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-027 Write to PM Array
Explanation: The Partition Manager continues. An explanatory sentence follows.
User Response: Probable PE error. Gather information about the problem and follow local
site procedures for reporting hardware and software problems.
0031-028 pm_mgr_handle; can't send a signal message to remote nodes
Explanation: The Partition Manager terminates. An explanatory sentence follows.
User Response: Probable PE error. This error has occurred in the Partition Manager signal
handler. Gather information about the problem and follow local site procedures for reporting
hardware and software problems.
52 IBM PE for AIX V2R4.0: Messages