IBM GC28-1982-02 Laptop User Manual


 
0031-403 0031-409
0031-403 Forcing dedicated adapter for User Space job
Explanation: User explicitly specified User Space job using -euilib us or MP_EUILIB=us
and poe is making sure the adapter usage requested from the Resource Manager is
dedicated. This can also occur if no euilib was specified and the execution environment
resulted in an implicit User Space job.
User Response: None required.
0031-404 Forcing shared adapter for IP job
Explanation: User explicitly specified IP job using -euilib ip or MP_EUILIB=ip and poe is
making sure the adapter usage requested from the Resource Manager is shared. This can
also occur if no euilib was specified and the execution environment resulted in an implicit IP
job.
User Response: None required.
0031-405 Hostfile entries for
string
usage for task
number
conflict, using
string
Explanation: User has hostfile entry which, for the same node, specifies shared AND
dedicated, or multiple AND unique, adapter or cpu usage, respectively.
User Response: Correct conflicting entries and rerun.
0031-406 IP not enabled for node
string
Explanation: The Resource Manager allocated a node which was not configured to run IP
over the switch.
User Response: Have the node configured for IP over the switch, or have the node
removed from the pool being used, or change the hostfile entry.
0031-407 LoadLeveler unable to allocate nodes to poe for batch job, rc =
number
Explanation: An internal error occurred in LoadLeveler. Reason codes are as follows:
-2 Could not get jobid from environment
-5 Socket error
-6 Could not connect to host
-8 Could not get hostlist
User Response: Retry; if problem persists, gather information about the problem and follow
local site procedures for reporting hardware and software problems.
| 0031-408
number
tasks allocated by LoadLeveler, continuing...
| Explanation: Loadleveler allocated the indicated number of nodes, which was different than
| that specified by the POE job (using MP_PROCS or -procs or default). The job is continued
| with the indicated number of nodes.
| User Response: If a fixed number of nodes is required, verify that the min_processors and
| max_processors keywords in the job command file agree with the number of nodes
| requested from POE. If they agree and the message continues, contact System
| Administrator to determine node availability.
| 0031-409 Unable to start Partition Manager daemon (
string
) on node
string
, rc =
|
number
| Explanation: An error (possibly internal) occurred when LoadLeveler attempted to start
| /etc/pmdv2 on the indicated node. Reason codes for internal LoadLeveler errors are as
| follows:
| 1 -- Remote host could not fork new process
| 2 -- Could not get jobid from environment
82 IBM PE for AIX V2R4.0: Messages