IBM SG24-4576-00 Server User Manual


 
IBM RAID Controller Configuration Ver 2.12
Adapter in Slot 1
┌────────────────────────────┐ ┌───────────┐ ┌───────────┐
Create/Delete Array │┌─────────┐│ │┌─────────┐│
├────────────────────────────┤ │└Ch 1┘│ │└Ch 2┘│
│1. Help │┌─Bay │┌─Bay
│2. Define hot-spare drive ││ Array ──┐│ ││ Array ──┐│
│3. Delete disk array ┌───── ┌─────┐
│4. Create disk array │1 └ │1 └
│5. Define Logical drive ┌───── ┌─────┐
│6. Format drive │2 └ │2 └
│7. Exit │ ┌─────┐ │ │ ┌─────┐ │
└────────────────────────────┘ │3 └ RDY ┘ │3 └
│ ┌─────┐ │ │ ┌─────┐ │
│4 └ RDY ┘ │4 └
│ ┌─────┐ │ │ ┌─────┐ │
│5 └ RDY ┘ │5 └
│ ┌─────┐ │ │ ┌─────┐ │
│6 └ RDY │6 └
│ ┌─────┐ │ │ ┌─────┐ │
│7 ┘ │ │7 ┘ │
└───────────┘ └───────────┘
Figure 60. RAID Configuration Program - Create/Delete Array Menu
1. Select Define hot-spare drive. The cursor becomes active in the Bay/Array
selection list.
2. Use the up and down arrow keys to select the RDY (ready) drive to be used
as a hot-spare and press Enter. The RDY status changes to HSP (hot-spare).
Figure 61 shows an example where a hot-spare disk has been defined.
3. Press Esc to validate.
Notes:
1. The hot-spare drive is not associated with any array. If more than one array
is defined, you need only 1 hot-spare drive for all the arrays.
2. If the disks have different sizes, the hot-spare drive must be the largest.
IBM RAID Controller Configuration Ver 2.12
Adapter in Slot 1
┌────────────────────────────┐ ┌───────────┐ ┌───────────┐
Create/Delete Array │┌─────────┐│ │┌─────────┐│
├────────────────────────────┤ │└Ch 1┘│ │└Ch 2┘│
│1. Help │┌─Bay │┌─Bay
│2. Define hot-spare drive ││ Array ──┐│ ││ Array ──┐│
│3. Delete disk array ┌───── ┌─────┐
│4. Create disk array │1 └ │1 └
│5. Define Logical drive ┌───── ┌─────┐
│6. Format drive │2 └ │2 └
│7. Exit │ ┌─────┐ │ │ ┌─────┐ │
└────────────────────────────┘ │3 └ HSP ┘ │3 └
│ ┌─────┐ │ │ ┌─────┐ │
│4 └ RDY ┘ │4 └
│ ┌─────┐ │ │ ┌─────┐ │
│5 └ RDY ┘ │5 └
│ ┌─────┐ │ │ ┌─────┐ │
│6 └ RDY │6 └
│ ┌─────┐ │ │ ┌─────┐ │
│7 ┘ │ │7 ┘ │
└───────────┘ └───────────┘
Figure 61. RAID Configuration Program - Hot-Spare Disk Definition
Chapter 3. Hardware Configuration 107