IBM Partner Pavilion BMD00082 Switch User Manual


 
SmartConnect User’s Guide
56
Chapter 4: Stacking BMD00082, February 2009
2. Verify that the software push is complete. Use either the CLI or the BBI:
From the BBI, go to Information > Stack and view the Image Push Status Information at
the bottom of the page, or
From the CLI, use following CLI command to verify the software push:
/info/stack/pushstat
3. Reboot all switches in the stack. From the BBI, select System Settings > Boot Man-
agement. Click Reboot Stack.
4. Once the switches in the stack have rebooted, verify that all of them are using the same
version of firmware. Using the BBI, open Information > Stack and view the Switch
Firmware Versions Information.
Image 1 transfer status info:
Switch 00:16:60:f9:33:00:
last receive successful
Switch 00:17:ef:c3:fb:00:
not received - file not sent or transfer in progress
Image 2 transfer status info:
Switch 00:16:60:f9:33:00:
last receive successful
Switch 00:17:ef:c3:fb:00:
last receive successful
Boot image transfer status info:
Switch 00:16:60:f9:33:00:
last receive successful
Switch 00:17:ef:c3:fb:00:
last receive successful
Config file transfer status info:
Switch 00:16:60:f9:33:00:
last receive successful
Switch 00:17:ef:c3:fb:00:
last receive successful