Intel 41210 Network Router User Manual


 
Intel
®
41210 Serial to Parallel PCI Bridge Developer’s Manual 73
Register Description
Register Description 12
This chapter describes the registers of the Intel
®
41210 Serial to Parallel PCI Bridge.
12.1 Register Nomenclature and Access Attributes
Table 32 describes the nomenclature used for describing bit attributes throughout this chapter.
Note: Software must not attempt to write to the registers that are marked “reserved”. Writing to these
registers yields undetermined results. Reads of these registers can yield either value. Note that the
behavior of individual register bits that are marked “reserved” is in accordance with the attribute
definition for that bit.
Table 32. Bit Attribute Definitions
Mnemonic Attribute
RO
Read-Only: This bit cannot be altered by software. This bit can be hard-wired to return a
fixed value at all times, or it can be set by hardware on an event.
RsvdP
Reserved and Preserved: These bits are reserved for future RW implementations; software
must preserve the value read for writes to bits. The Intel
®
41210 Serial to Parallel PCI Bridge
hardware implements these bits as read-only 0s.
RsvdZ
Reserved and Zero: These bits are reserved for future RWC implementations; software must
use 0 for writes to bits. The 41210 hardware implements these bits as read-only 0s.
ROS
Read-Only Sticky: These bits are read-only and cannot be altered by software. The bits are
not cleared by reset and can be reset only with the
PERST# reset condition.
RZSet
Read Zero to Set: Reading this bit when the current value of the bit is 0 causes the bit to flip
to a 1. Software must write a 1 to clear this bit. Writing a 0 has no effect.
RW
Read-Write: Software can do a full read and write of this bit.
RW1Set
Read and Write One to Set: Software must write a 1 to set this bit. Writing a 0 has no effect
on this bit. Software can clear this bit through a separate RWC bit, or it can be reset by
hardware.
RWS
Read-Write and Sticky: Software can read and write this bit. The bit can be reset only by a
PERST# reset.
RWC
Read and Write One to Clear: When this bit is set, software must write a 1 to this bit to clear
it. Writing a 0 has no effect.
RWCS
Read and Write One to Clear and Sticky through reset: When this bit is set, software must
write a 1 to this bit to clear it. Writing a 0 has no effect. The bit can be reset only by a
PERST#
reset.
Strap
Strap: This is a read-only register. The power-on default is based on sampling a strap pin at
the rising edge of
PERST#.
WT
Write Transient: This bit is always read as a 0. Writing a 1 to this bit causes other side-
effects that are specific to every WT bit.