Intermec 6400 Laptop User Manual


 
APPENDIX B
Norand
R
Utilities Program
6400 Hand-Held Computer User’s Guide
B-13
These error codes apply when COMM SETTINGS is set to
NOVELL NETWARE:
"
“0”
No error
“6”
User aborted communications by pressing
[--]
key.
“100”
Connection to host failed. Verify network
connection, verify that PENKEY login name
exists on host.
“101”
Could not access include file. Verify existence
of include file on host.
“102”
Could not allocate needed memory.
These error codes apply when COMM SETTINGS is set to
NRINET:
"
“0”
No error
“6”
User aborted communications by pressing
[--]
key.
“800”
PC TCP/IP kernel is missing.
“801”
Invalid client IP address. Make sure the entry
for CLIENT IP ADDRESS is correct, or make
sure the DHCP server is running.
“802”
Invalid Service or Service Type, or invalid port
number.
“803”
Invalid host name or IP Address. Make sure
the entry for SERVER NAME is correct, and
that the server is running.
“804”
Could not create socket. Check all cables and
network connections.
“806”
Block sent was incomplete or block received
was incomplete.
“807”
Client and server negotiation failed.
“808”
Server specified an unsupported block s ize.
“809”
Invalid buffer pointer.
“810”
All server connections are already in use. Try
again later.