Setting Your DOS Application to
Accept Tethered Laser Scanners
In AUTOEXEC.BAT, ensure the scanner driver is loaded in
the PS/DOS section with 64SCN7B --E --W --T1 I0 (this is
for wedge scanning).
Setting Up Your LS3203 or LS3603
RS-232 Serial Scanner Parameters
Tethered laser power is always on, so a tethered laser can
scan, decode, and send the data as soon as it is connected,
even when it is not properly configured. Therefore, proper
operation of the tethered laser is no indication that the la-
ser is correctly configured for the scanner driver 64SCN7B.
Scan the following bar codes to set up your LS3203ER-
I200A or LS3603-I200A scanner so it will work with your
hand-held computer. You need to scan all the bar codes (ex-
cept for the Host Transmit Code ID Character and Host De-
code Options) to enable your laser scanner to work with the
64SCN7B scanner driver on your computer.
Set All Defaults
Scan the Set All Defaults bar code to set up your scanner
for RS-232 serial communication.