4: Web Manager Configuration
WiBox® 2100E Device Server User Guide 39
Figure 4-7. UDP Connection Settings
2. In the available fields, enter the following information:
Datagram Mode
Datagram Type
Configures remote IP or network broadcast address and the remote
port. Enter 01 for directed or broadcast UDP. The default setting is 00.
Accept Incoming Select Yes to accept incoming UDP datagrams.
Endpoint Configuration
Local Port
Enter the local port number.
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Use Broadcast
Select to broadcast the UDP datagram. Datagrams of type 01 can be
sent as a broadcast by enabling this option. The default is not to
broadcast.
Note:
Datagrams are sent as subnet-directed broadcasts.
Device Address Table
Enter values in the range 1-255 to identify units on the local network of
device servers.
Note: Lantronix Tech Support supports Datagram type 01. Datagram
type FD is for OEM use. This table is enabled when Datagram Type is
set to FD.