Lantronix 2100E Network Router User Manual


 
WiBox® 2100E Device Server User Guide 67
8: Setup Mode: Advanced Settings
Expert Settings (Option 5)
Note: You can change these settings using Telnet or serial connections only, not Web
Manager.
Caution: Only an expert should change these parameters. You must definitely know the
consequences the changes may have.
Figure 8-1. Expert Settings
TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?
ARP Cache timeout in s (1s - 600s) : (600) ?
CPU performance (0=Regular, 1=Low, 2=High): (0) ?
Disable Monitor Mode @ bootup (N) ?
HTTP Port Number : (80) ?
MTU Size (512 - 1400): (1400) ?
TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?
Enable alternate MAC (N) ?
Ethernet connection type: (0) ?
Note: The Config Server Port Number option and Automatic Host MAC Detection option
display only in Bridging mode as shown in the next window. For more information, see
Configurable Server Port Number and Automatic Host MAC Detection on page 69.
The default settings are listed below:
TCP Keepalive time in s
(1s 65s; 0s=disable)
45
ARP Cache timeout in s
(1s 600s)
600
CPU Performance
Regular
Disable Monitor Mode @ bootup
N (No) (resulting in Monitor Mode enabled)
HTTP Port Number
(1-65535)
80
MTU Size (512 1400)
0 (resulting in an operational value of 1400)
TCP Re-transmission Timeout
(500 - 4000) (ms)
500
Enable alternate MAC
Disabled (OEM use only)
Ethernet connection type
0 (resulting in auto-negotiation)
Config Server Port Number
30718
Automatic Host MAC Detection
Y (Yes)