WiBox® 2100E Device Server User Guide 49
7: Setup Mode: Channel Configuration
This chapter explains how to configure the serial port.
Notes:
Current values display in parenthesis.
You must enter some values in hexadecimal notation. (See B: Binary to Hexadecimal
Conversions on page 88.)
Channel 1 (Option 1)
Select Channel 1 (option 1) from the Change Setup menu to define how the serial port responds
to network and serial communications. The following sections describe the configurable
parameters within the Channel configuration menu.
Figure 7-1. Serial Port Parameters
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?
Send '+++' in Modem Mode (Y) ?
Show IP addr after 'RING' (Y) ?
Auto increment source port (N) ?
Remote IP Address : (000) .(000) .(000) .(000)
Remote Port (0) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ?
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or baud rate to
use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default),
19200, 38400, 57600, 115200, 230400, 460800, or 921600. Enter a baud rate of 00 in channel
settings to disable the serial port. The current value is displayed in parentheses.
Baudrate (9600) ? _