Mitsubishi Electronics QJ71C24/-R2 Network Card User Manual


 
3 - 26 3 - 26
MELSEC-Q
3 SPECIFICATIONS
Address
Decimal (Hex)
Applicable
protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi
Registration
allowed/not
allowed
Reference
section
7486 to 7526
(1D3EH to 1D66H)
For registration No. 800F
H
7527 to 7567
(1D67H to 1D8FH)
For registration No. 8010
H
7568 to 7608
(1D90H to 1DB8H)
For registration No. 8011
H
7609 to 7649
(1DB9
H
to 1DE1
H
)
For registration No. 8012
H
7650 to 7690
(1DE2H to 1E0AH)
For registration No. 8013
H
7691 to 7731
(1E0BH to 1E33H)
For registration No. 8014
H
7732 to 7772
(1E34H to 1E5CH)
For registration No. 8015
H
7773 to 7813
(1E5DH to 1E85H)
For registration No. 8016
H
7814 to 7854
(1E86H to 1EAEH)
For registration No. 8017
H
7855 to 7895
(1EAFH to 1DE7H)
For registration No. 8018
H
7896 to 7936
(1ED8H to 1F00H)
For registration No. 8019
H
7937 to 7977
(1F01H to 1F29H)
For registration No. 801A
H
7978 to 8018
(1F2AH to 1F52H)
For registration No. 801B
H
8019 to 8059
(1F53H to 1F7BH)
For registration No. 801C
H
8060 to 8100
(1F7CH to 1FA4H)
For registration No. 801D
H
8101 to 8141
(1FA5H to 1FCDH)
For registration No. 801E
H
8142 to 8182
(1FCEH to 1FF6H)
For registration No. 801F
H
The user registration area has the following combined uses, with
data written by the user according to the purpose of use by the
TO instruction, etc.
See each explanation item concerning the configuration of each
area, the data written, etc.
(1) If data communications is being carried out by user
registration frame.
• User registration frame (User’s Manual (Application),
Chapter 9)
(2) If data communications is being carried out by the modem
function.
• Initialization Data (User’s Manual (Application) Section
3.4.3)
• Connection Data (User’s Manual (Application) Section
3.4.4)
Not allowed
Refer to left
description
8183 to 8191
(1FF7
H
to 1FFF
H
)
Use prohibited System area
Flash ROM write allow/prohibit designation
8192
(2000
H
)
System
designation
0: Write prohibited 1: Write allowed
0 RW Not allowed
Section
8.4.12
8193
(2001
H
)
Callback function designation
0
H
: Auto
1
H
: Callback connection (during fixed)·····························(Setting 4)
3
H
: Callback connection (during designated number)·····(Setting 5)
7
H
: Callback connection
(during max. designated number is 10)·····················(Setting 6)
9
H
: Auto/Callback connection (during fixed)·····················(Setting 1)
B
H
: Auto/Callback connection
(during designated number)·······································(Setting 2)
F
H
: Auto/Callback connection
(during max. designated number is 10)·····················(Setting 3)
0
8194
(2002
H
)
For callback
function
Callback denial notification accumulated count designation
0
H
: Not specified
1
H
to FFFF
H
: Notification accumulated number count
1
RW
Allowed
Section
8.4.4
Chapter 3 of
User’s
Manual
(Application)
8195 to 8198
(2003
H to 2006H)
Use prohibited System area
8199
(2007
H
)
Auto modem initialization designation
0: Do not auto initialize 1: Auto initialize
0
Modem initialization time DR (DSR) signal valid/invalid designation
8200
(2008
H
)
0: Do not ignore DR signal. 1: Ignore DR signal.
1
Complete signal handling for modem function designation
8201
(2009
H
)
0: Do not turn on/off X13 to X16.
1: Turn on/off X13 to X16.
1
8202
(200A
H
)
For designation
of modem
function -2
Wait time of notification designation
0000
H
to FFFF
H
: Wait time (unit: s)
10
RW Allowed
Section
8.4.4
Chapter 3
of User's
Manual
(Application)
8203
(200B
H
)
Use prohibited System area
8204
(200C
H
)
Remote password mismatch notification count designation
0
H
: No designation
1
H
to FFFF
H
: Notification times
0
8205
(200D
H
)
For remote
password
function
Remote password mismatch notification accumulated count
designation
0
H
: No designation
1
H
to FFFF
H
: Cumulative times of notification
1
RW
Allowed
Section 5.1.5
Section 8.4.4
Chapter 3 of
User's
Manual
(Application)