162
replication operation option setting file. On the UNIX system, the default value can be specified
by using the RPL_WATCHDEV environment variable. For details of each setting, refer to the
“Data Replication Command Reference”.
(4) Paired-volume state monitoring time limit (-limit)
You can specify a time limit for stopping the monitoring of the paired-volume state. If the Wait
is not completed before the elapse of the specified time, it is discontinued and the command ends
abnormally.
y Time specification (-limit [second])
A value (in seconds) specified for [second] is the monitoring time limit. A value from 0 to
86,400 seconds (integer) can be specified.
y No limit (-limit nolim)
Unlimited wait.
On the Windows system, the default value can be specified by using RPL_LIMWATCHDEV in the
replication operation option setting file. On the UNIX system, the default value can be specified by
using the RPL_LIMWATCHDEV environment variable. For details of each setting, refer to the “Data
Replication Command Reference”.
[Displayed Information]
The iSMrc_wait command displays the following message during Wait execution and when Wait ends.
On the Windows system
[Execution message]
Waiting...
[End message]
activity_state Normal End YYYY/MM/DD hh:mm:ss
MV:disk_number ld_name type
volume_name
path
RV:disk_number ld_name type
volume_name
path
Description
If you do not want the execution message to appear, change the RPL_WAITMSG setting in the
replication operation option setting file. Information about the replication operation option