Netopia PN Series Network Router User Manual


 
2-32 Reference Guide
Frame Relay Configuration
LMI Type... ANSI (Annex D)
T391 (Polling Interval in secs): 10
N391 (Polls/Full Status Cycles): 6
N392 (Error Threshold): 3
N393 (Monitored Event Window): 4
Tx Injection Management... Standard
Default CIR: 64000
Default Bc: 64000
Default Be: 0
Congestion Management Enabled: Yes
Maximum Tx Frame Size: 1536
Enter Information supplied to you by your telephone company.
1. Select LMI Type (Link Management Type) and press Return. From
the pop-up menu, highlight either ANSI (Annex D), CCITT (Annex
A), LMI, or None. The world-wide default is ANSI (Annex D).
Press Return.
Note: If you select None as an LMI Type, the four LMI options
listed below will remain hidden, and you will need to manually
configure DLCIs. See “Frame Relay DLCI configuration” on
page 2-34 for instructions.
Specifying the Link Management Type is the first step in
configuring Frame Relay.
If you select an LMI Type (Link Management Type) other than
None, the T391 option specifies the number of seconds
between the Status Enquiry messages. The default setting is
10.
The N391 option specifies the frequency of full status polls,
in increments of the basic (T391) polling cycle. The default
setting is 6.