Oki OF5800 Fax Machine User Manual


 
Page: 120
Service Manual for OF5800
Chapter 3 Adjustment Procedures
The life monitor displays the current software version and the total number of pages scanned, printed, and
transmitted.
1. Press
PROGRAM, *, 9 , ENTER.
2.
Press One-touch A-D to select the desired display. Press
STOP
to exit the test mode.
NOTE:
The following options are available:
One-touch A = displays software version*
* If option boards are installed, press 0 for the unit itself; 1 (and 2) are for installed board revisions
One-touch B = displays total pages scanned
One-touch C = displays total pages printed
One-touch D = displays total pages transmitted
One-touch E = displays drums replaced count
One touch F = displays current drum count
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business