Chapter 3 Adjustment Procedures
Bit
Initial Setting Adjustment Usage / Comments
7 0 Factory use only
6 0 Factory use only
5 0 Factory use only
4 0 Factory use only
3 0 Factory use only
2 1 Background level
0: Automatic
1: Fixed
The background level measures the reflective
ability of scanned documents. Performed with
each transmission or copy function.
1 0 Effective scan width
0: Q4 = 208 mm (8.2") Default
1: A4 = 216 mm (8.5") Full width (edge to edge)
(The unit must be turned off, then on, for this change to take effect).
0 1 Document TX length
limit
0: Unlimited
1: 1 meter
Setting to unlimited will override document jam
sensing.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business